A personal wellness project built around wearable ECG recording and experimental blood pressure estimation. The ambition is meaningful, but reliable measurements take careful research and validation.
Wellness Companion has evolved into a phone-and-watch project with ECG tools, profiles, measurement history, backup and restore, and experimental blood pressure workflows. ECG is in public beta, and experimental BP testing is underway.
Blood pressure research is the priority. BP V4.1 has been published for testing alongside Aurora V3, with more varied PPG recordings, signal-quality investigation, subject-separated evaluation and comparison with cuff references. No wearable estimate has been established as a replacement for a validated cuff.
What happens next
01 · In progressEvaluate BP V4.1 and Aurora V3
Evaluate the new hybrid research approach, improve signal quality and reduce systematic estimation errors using carefully separated datasets.
02 · ValidationCollect and compare more real measurements
Continue testing with user-provided cuff references and more varied recording conditions.
03 · After sufficient evidenceRefine the user-facing experience
Use validated findings to guide reliability work and communication of limitations in the eventual broader beta.
Important: Experimental blood pressure estimates are not established as a replacement for a validated medical cuff, and this project should not be relied upon for diagnosis or treatment decisions.
THE DEVELOPMENT STORY · 2025–2026
How a personal idea became a long research journey.
There is a lot more behind Wellness Companion than the latest version number. Some ideas worked. Others needed rewriting, more evidence, or a complete change of direction. This is my account of that journey, including the setbacks that shaped it.
01The beginning
THE ORIGIN
When one chapter ended, I decided to build my own.
After years working on SHM Mod, changes to the ecosystem made continuing that project impractical. I wanted to take what I had learned from Samsung watch sensors and create an independent Android-and-Wear OS wellness experience: one I could maintain, explain, and improve over time.
Why start again?
It meant accepting the hard parts as well as the freedom: phone/watch communication, sensor readiness, signal processing, measurement history, privacy and careful communication of what a wellness app can and cannot establish. I deliberately built around the supported Samsung Galaxy Watch hardware and available sensor SDKs, rather than promising universal wearable compatibility.
02Closed testing
ECG · PRIVATE TESTING
ECG became the first serious proving ground.
ECG entered closed testing in March. The priority was not just displaying a waveform, but making a 30-second recording dependable: a 500 Hz acquisition path, sensor-ready countdowns, finger-contact checks, timeouts, and clear cancellation or retry behavior when a recording could not be trusted.
What made ECG recording more stable?
A 20-second heart-rate warmup helped prepare the watch; the 3-second steady-position countdown began only after sensor readiness and contact, with a separate 5-second option. Samples from the countdown did not enter the recording. Contact loss, excessive noise and stalled measurements had to end in clear outcomes instead of silently producing misleading results.
These improvements concern acquisition reliability and signal quality. They are not a claim that an ECG interpretation is medically diagnostic.
03Public beta
ECG · PUBLIC BETA
From closed testers to a public beta.
In June, the ECG-focused Wellness Companion reached public beta. By then, recording, viewing results, measurement history and the surrounding phone/watch workflow had become much more mature. Feedback still mattered: a reliable recording flow is something earned through repeated testing, not assumed from a successful demonstration.
What does ECG stability mean here?
There are several separate pieces: acquiring a complete signal, recognizing contact or noise problems, storing the result correctly, and presenting an understandable explanation. The app developed explainable signal-quality indicators alongside ECG analysis. A completed, good-quality recording is still wellness information, not a medical diagnosis or a substitute for a clinical ECG assessment.
04Research begins
BP · DATASET HUNT
Before training a blood pressure model, I had to find the data.
July was spent hunting for suitable paired waveform and blood pressure data. A pulse waveform alone is not a reference BP reading. I needed to investigate public research datasets, signal formats, sample rates, cuff or arterial-pressure reference quality, participant separation and whether anything learned from them could transfer to a Galaxy Watch.
Why was finding data so difficult?
Research waveforms are not interchangeable with wrist PPG captured in daily life. Sampling differences, noisy recordings, missing pairs and duplicated participants can make a model look better on paper than it behaves on a person. That gap between laboratory data and an actual watch became a recurring theme in later experiments.
05A real setback
BEHIND THE SCENES
Before V1 could move forward, the development laptop failed.
A GPU fan failure and an SSD thermal failure disrupted the planned BP work in August. Development had to pause while I dealt with the hardware problems. The setback delayed the project and pushed later roadmap phases back; it was not a model-quality result or a reason to claim that research data had been lost.
How that changed the roadmap
Blood pressure research took priority over later wellness features, and I revised the schedule instead of pretending the original dates still applied. Fixing the laptop and getting the development environment working again came before returning to the BP model.
06Development resumed
BP V1 · MODEL DEVELOPMENT
After the repair, I returned to the first BP model.
Once the laptop was repaired, September became the period of renewed V1 research and development. I worked on translating PPG features into experimental systolic and diastolic estimates, comparing predictions with cuff readings, and building a calibration workflow around repeated reference measurements.
What V1 taught me
V1 made the end-to-end experiment possible, but its weaknesses were real: diastolic readings often came out too low, systolic readings could be elevated, and signal quality varied. The calibration experience eventually developed three required reference readings with two optional extras, a 28-day validity window and wrist-consistency safeguards. Even with calibration, a plausible-looking number cannot be assumed accurate.
07Closed BP testing
BP · CLOSED TESTING
Real wrists and real cuffs exposed the difficult cases.
Around the beginning of October, BP entered closed testing. People compared the watch's experimental estimates with readings from a separate blood pressure cuff. Repeated recordings, calibration integrity, wrist selection and the conditions around each measurement mattered just as much as the number displayed on the screen.
Why the cuff comparisons matter
A model can appear consistent while being consistently wrong. Reviewing paired reference readings helps reveal bias and spread across different people and situations. The app keeps the cuff workflow distinct from the watch estimate. The experimental result is not a replacement for a validated cuff, particularly when accuracy has not been established across a suitable population.
08Research-only
BP V2 · RETHINKING THE MODEL
A stronger-looking research pipeline met a stubborn watch reality.
V2 explored a larger, more disciplined dataset pipeline, including MIMIC-III Extended PPG, resampling to 100 Hz, subject-blocked evaluation and stronger signal-quality screening. Yet many real on-watch recordings were classified as low signal. That mismatch made V2 unsuitable for replacing the active measurement workflow, so it remained research-only and was retired.
What I carried forward from V2
Separating participants between training and evaluation helps reduce overly optimistic results. Keeping waveform sources traceable and auditing rejection reasons matter too. Most importantly, a promising offline metric is not the same as dependable wrist performance. Those lessons shaped the design of V3.
09New experience
PHONE + WATCH · INTERFACE REVAMP
The app needed to feel as thoughtful as the research behind it.
Alongside model work, I rebuilt much of the phone experience. Classic, Material and One UI appearances, accent palettes, light/dark preferences and immediate previews gave people more choice without changing what their recordings mean. The effort also covered onboarding, dialogs, translations, history screens and more predictable notifications.
Design and reliability are connected
Readable errors, obvious calibration states and consistent dialogs reduce confusion when a sensor or estimate is unavailable. ECG and BP should notify only when a result is actually ready. Styling is not cosmetic if the interface is how a tester understands uncertainty, retries a failed reading or catches a calibration problem.
10Research milestone
BP V3 · AURORA
V3 brings the lessons together, but it is still experimental.
The Aurora V3 work combines lessons from V1 and V2 with a broader hybrid research approach, varied PPG sources, participant-separated evaluation, quality checks and closer attention to systematic systolic/diastolic errors. The latest research model has been integrated into development builds for controlled testing.
Why a third generation is not the finish line
V3 can still return readings that are noticeably off, even when another result looks close to a cuff. More paired real-world measurements are needed to examine different wrists, signal conditions and calibration ages. A planned next iteration, V4, can learn from carefully shared tester feedback without assuming any individual reading is correct. BP V3 is not clinically validated.
11Experimental development
BP V4 · PERSONALIZED RESEARCH
What if the model learned more from the individual?
I introduced personalized V4 alongside Aurora V3 for experimental comparisons against cuff references.
Why keep both models?
The comparison investigates whether personalized calibration improves independent estimates. Improved accuracy has not been established.
12Published · Testing underway
BP V4.1 · EXPERIMENTAL TESTING
V4.1 is published, and testers are joining.
The next phase gathers real-world feedback and watch/cuff comparisons.
What comes next?
BP V4.1 remains experimental and is not clinically validated.
13In development
BP · CALIBRATION RESEARCH
A better reference starts with both arms.
I am exploring bilateral cuff screening and explicit calibration protocols.
Why change calibration?
The aim is to investigate inter-arm reference differences. This feature is still in development.
14Hopeful target
BP · WHAT I HOPE COMES NEXT
Could December bring a more stable BP release?
That is the hope, if all goes well. My goal for December is a more stable experimental BP model and, if the real-world evidence supports it, a broader release. It is a target, not a guarantee: validation, calibration reliability, signal quality and honest communication of uncertainty matter more than meeting a calendar date.
What would make that possible?
More paired watch/cuff measurements across different people and recording conditions, a careful review of the remaining systematic errors, and enough evidence that the next model behaves more consistently. If those checks do not support release, the responsible choice is to keep improving it rather than publish an unproven promise. A more stable experimental model would still not be a clinically validated alternative to a medical cuff.
THE NEXT CHAPTER
More recordings. Better questions. More honest answers.
I want testers to record watch estimates alongside cuff measurements over several days and share their chosen exports for comparison. That feedback may help improve future models, but I would rather show uncertainty clearly than make a promise the evidence cannot support.
Where things stand: ECG's recording workflow has progressed through closed testing and a public beta. BP V4.1 testing is underway; bilateral screening is in development. Neither an ECG interpretation nor a wrist BP estimate in this app should be used for medical diagnosis, and a watch estimate is not an alternative to a validated cuff.
THE ORIGINAL PUBLISHED PLAN
Four phases, one long-term vision.
The complete illustrated Wellness Companion roadmap is published on GitHub. The phase targets are historical planning estimates, not release guarantees.
Follow the complete journey
From ECG fundamentals to careful blood-pressure research, broader wellness features, and the final round of integration and polish. Each phase has its own illustrated page on GitHub.
These phases describe a development vision, not a claim that experimental BP estimation is medically accurate or clinically validated. Actual priorities are reflected in the manually maintained multi-project roadmap.